CCS Graad EH40 Skeepsbou Staalplaat
C maks |
Si maks |
Mn |
P maks |
S maks |
Als |
NB |
V |
Ti maks. |
Cu maks. |
Cr maks. |
Ni maks. |
Ma maks. |
N maks. |
0.18 |
0.50 |
0.90-1.60 |
0.025 |
0.025 |
0.015 |
0.02-0.05 |
0.05-0.10 |
0.02 |
0.35 |
0.20 |
0.40 |
0.08 |
- |
Opbrengssterkte (MPa) min. |
Treksterkte (MPa) |
Verlenging min. % |
390 |
510-660 |
20 |
CCS Graad FH40 Skeepsbou Staalplaat
C maks |
Si maks |
Mn |
P maks |
S maks |
Als |
NB |
V |
Ti maks. |
Cu maks. |
Cr maks. |
Ni maks. |
Ma maks. |
N maks. |
0.16 |
0.50 |
0.90-1.60 |
0.020 |
0.020 |
0.015 |
0.02-0.05 |
0.05-0.10 |
0.02 |
0.35 |
0.20 |
0.80 |
0.08 |
0.009 |
Opbrengssterkte (MPa) min. |
Treksterkte (MPa) |
Verlenging min. % |
390 |
510-660 |
20 |
CCS Graad AH40 Skeepsboustaalplaat
C maks |
Si maks |
Mn |
P maks |
S maks |
Als |
NB |
V |
Ti maks. |
Cu maks. |
Cr maks. |
Ni maks. |
Ma maks. |
N maks. |
0.18 |
0.50 |
0.90-1.60 |
0.030 |
0.030 |
0.015 |
0.02-0.05 |
0.05-0.10 |
0.02 |
0.35 |
0.20 |
0.40 |
0.08 |
- |
Opbrengssterkte (MPa) min. |
Treksterkte (MPa) |
Verlenging min. % |
390 |
510-660 |
20 |
CCS Graad EH36 Skeepsbou Staalplaat
C maks |
Si maks |
Mn |
P maks |
S maks |
Als |
NB |
V |
Ti maks. |
Cu maks. |
Cr maks. |
Ni maks. |
Ma maks. |
N maks. |
0.18 |
0.50 |
0.90-1.60 |
0.025 |
0.025 |
0.015 |
0.02-0.05 |
0.05-0.10 |
0.02 |
0.35 |
0.20 |
0.40 |
0.08 |
- |
Opbrengssterkte (MPa) min. |
Treksterkte (MPa) |
Verlenging min. % |
355 |
490-630 |
21 |
CCS/E Normale Sterkte Max Chemiese Samestelling in Warmgewalste
Element |
CCS E Max % |
Element |
CCS E Max % |
C |
0.21 |
Ni |
|
Mn |
0.60 |
Ma |
|
Si |
0.1-0.35 |
Al |
|
S |
0.035 |
NB |
|
P |
0.035 |
V |
|
Cu |
|
Ti |
|
Kr |
|
N |
|
Kraakgevoeligheid: Pcm = (C+Si/30+Mn/20+Cu/20+Ni/60+Cr/20+Mo/15+V/10+ 5B)%
Koolstofekwivalent: Ceq = 【C+Mn/6+(Cr+Mo+V)/5+(Ni+Cu)/15】%
CCS/E Normale sterkte-eienskap in Warmgewalste
Graad |
Dikte |
Lewer krag |
Trek sterkte |
Verlenging |
Impak Energie |
(mm) |
MPa (min) |
MPa |
% (min) |
(KV J) (min) |
|
|
|
|
|
-20 grade |
|
CCS E |
8-240 |
235 |
400-520 |
22 |
27J |
Let wel: die impakenergie onder minder 50 mm dikte; longitudinale min impak energie
CCS/D normale sterkte maksimum chemiese samestelling in warmgewalste
Element |
CCS D Maksimum % |
Element |
CCS D Maksimum % |
C |
0.21 |
Ni |
|
Mn |
0.60 |
Ma |
|
Si |
0.1-0.35 |
Al |
|
S |
0.035 |
NB |
|
P |
0.035 |
V |
|
Cu |
|
Ti |
|
Kr |
|
N |
|
Kraakgevoeligheid: Pcm = (C+Si/30+Mn/20+Cu/20+Ni/60+Cr/20+Mo/15+V/10+ 5B)%
Koolstofekwivalent: Ceq = 【C+Mn/6+(Cr+Mo+V)/5+(Ni+Cu)/15】%
CCS/D Normale sterkte-eienskap in warmgewalste
Graad |
Dikte |
Lewer krag |
Trek sterkte |
Verlenging |
Impak Energie |
(mm) |
MPa (min) |
MPa |
% (min) |
(KV J) (min) |
|
|
|
|
|
-20 grade |
|
CCS D |
8-240 |
235 |
400-520 |
22 |
27J |
Let wel: die impakenergie onder minder 50 mm dikte; longitudinale min impak energie
CCS/B normale sterkte maksimum chemiese samestelling in warmgewalste
Element |
CCS B Maksimum % |
Element |
CCS B Maksimum % |
C |
0.21 |
Ni |
|
Mn |
0.80 |
Ma |
|
Si |
0.35 |
Al |
|
S |
0.035 |
NB |
|
P |
0.035 |
V |
|
Cu |
|
Ti |
|
Kr |
|
N |
|
Kraakgevoeligheid: Pcm = (C+Si/30+Mn/20+Cu/20+Ni/60+Cr/20+Mo/15+V/10+ 5B)%
Koolstofekwivalent: Ceq = 【C+Mn/6+(Cr+Mo+V)/5+(Ni+Cu)/15】%
CCS/B Normale sterkte-eienskap in warmgewalste
Graad |
Dikte |
Lewer krag |
Trek sterkte |
Verlenging |
Impak Energie |
(mm) |
MPa (min) |
MPa |
% (min) |
(KV J) (min) |
|
|
|
|
|
0 graad |
|
CCS B |
8-240 |
235 |
400-520 |
22 |
27J |
Let wel: die impakenergie onder minder 50 mm dikte; longitudinale min impak energie
CCS/A Normale sterkte maksimum chemiese samestelling in warmgewalste
Element |
CCS A Maksimum % |
Element |
CCS A Maksimum % |
C |
0.21 |
Ni |
|
Mn |
2.5*C MIN |
Ma |
|
Si |
0.50 |
Al |
|
S |
0.035 |
NB |
|
P |
0.035 |
V |
|
Cu |
|
Ti |
|
Kr |
|
N |
|
Kraakgevoeligheid: Pcm = (C+Si/30+Mn/20+Cu/20+Ni/60+Cr/20+Mo/15+V/10+ 5B)%
Koolstofekwivalent: Ceq = 【C+Mn/6+(Cr+Mo+V)/5+(Ni+Cu)/15】%
CCS/A Normale sterkte-eienskap in warmgewalste
Graad |
Dikte |
Lewer krag |
Trek sterkte |
Verlenging |
Impak Energie |
(mm) |
MPa (min) |
MPa |
% (min) |
(KV J) (min) |
|
|
|
|
|
20 grade |
|
CCS A |
8-240 |
235 |
400-520 |
22 |
|
Let wel: die impakenergie onder minder 50 mm dikte; longitudinale min impak energie